PURGE VALVE (for Sedan) > INSPECTION



1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY


A117793
  1. Check the resistance.

    1. Using an ohmmeter, measure the resistance between the terminals.

      Standard resistance:
      Tester Connection
      Specified Condition
      1 - 2
      23 to 26 Ω at 20°C (68°F)
      If the resistance is not as specified, replace the vacuum switching valve assembly.


    A117794E01
  1. Check the operation.

    1. Check that air does not flow from port E to F.



    2. A117795E01
    3. Apply battery voltage across the terminals.

    4. Check that air flows from port E to F.
      If the operation is not as specified, replace the vacuum switching valve assembly.