AIR FUEL RATIO SENSOR > ON-VEHICLE INSPECTION |
for Preparation Click here
1. INSPECT AIR FUEL RATIO SENSOR |
Disconnect the 2 sensor connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 (HA1A) - 2 (+B)
(for Bank 1)20°C (68°F) 1.6 to 3.2 Ω 1 (HA2A) - 2 (+B)
(for Bank 2)
Reconnect the 2 sensor connectors.