Tacoma

Toyota Tacoma 2015-2018 CAN Workshop Manual

OK
OK
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER
CONNECTION
CONDITION SPECIFIED
CONDITION
D4-6 (CANH) -
D4-4 (CG)
Cable disconnected from
negative (-) battery terminal
200 Ω or higher
D4-14 (CANL) -
D4-4 (CG)
Cable disconnected from
negative (-) battery terminal
200 Ω or higher
Text in Illustration
*1 DLC3
NG
GO TO SHORT TO GND IN CAN BUS LINE
9. CHECK FOR SHORT TO +B IN V BUS (CANH, CANL - BAT)
(a) Measure the resistance according to the value(s) in the table
below.
Standard Resistance:
TESTER
CONNECTION
CONDITION SPECIFIED
CONDITION
D4-6 (CANH) -
D4-16 (BAT)
Cable disconnected from
negative (-) battery terminal
6 kΩ or higher
D4-14 (CANL) -
D4-16 (BAT)
Cable disconnected from
negative (-) battery terminal
6 kΩ or higher
Text in Illustration
*1 DLC3
NG
GO TO SHORT TO +B IN CAN BUS LINE
cardiagn.com

Leave a Reply

Your email address will not be published. Required fields are marked *