Title: AIR CONDITIONING: FRONT EVAPORATOR TEMPERATURE SENSOR: INSPECTION; 2016 MY Tacoma
[08/2015 - ]
INSPECTION
1. INSPECT COOLER THERMISTOR SENSOR
(a) Check the resistance.
(1) Measure the resistance and check the results in accordance
with the values in the table below.
Standard:
TESTER CONNECTION CONDITION SPECIFIED CONDITION
1 - 2 -10°C (14°F) 7.40 to 9.20 kΩ
1 - 2 -5°C (23°F) 5.65 to 7.00 kΩ
1 - 2 0°C (32°F) 4.35 to 5.40 kΩ
1 - 2 5°C (41°F) 3.40 to 4.20 kΩ
1 - 2 10°C (50°F) 2.68 to 3.30 kΩ
1 - 2 15°C (59°F) 2.10 to 2.60 kΩ
1 - 2 20°C (68°F) 1.66 to 2.10 kΩ
1 - 2 25°C (77°F) 1.32 to 1.66 kΩ
1 - 2 30°C (86°F) 1.05 to 1.35 kΩ
If the result is not as specified, replace the cooler thermistor
sensor.
NOTICE:
E
ven slightly touching the sensor may change the resistance
value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be almost the
same as the ambient temperature.