Tacoma

Toyota Tacoma 2015-2018 Air Conditioning Workshop Manual

A
OK
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn the Techstream on.
(d) Enter the following menus: Body Electrical / Air Conditioner / Data List.
(e) Check the value(s) by referring to the table below.
Air Conditioner
TESTER DISPLAY MEASUREMENT ITEM/RANGE NORMAL CONDITION DIAGNOSTIC
NOTE
Room Temperature
Sensor
Cooler thermistor (room temperature
sensor) /
min.: -6.50°C (20.30°F)
max.: 57.25°C (135.05°F)
Actual cabin temperature
displayed
-
OK:
The display is as specified in the Normal Condition column.
RESULT PROCEED TO
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC) C
B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN
PROBLEM SYMPTOMS TABLE
C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY
2. INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)
(a) Remove the cooler thermistor (room temperature sensor) .
(b) Inspect the cooler thermistor (room temperature sensor) .
NG
REPLACE COOLER THERMISTOR (ROOM
TEMPERATURE SENSOR)