INSPECTION
1. INSPECT AMBIENT TEMPERATURE SENSOR
(a) Measure the resistance according to the value(s) in the table
below.
Standard resistance:
TESTER CONNECTION CONDITION SPECIFIED CONDITION
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
1 - 2 60°C (140°F) 0.36 to 0.50 kΩ
NOTICE:
E
ven slightly touching the sensor may change the resistance
value. Be sure to hold the sensor connector.
When measuring, the sensor temperature must be the same as
the ambient temperature.
HINT:
As the temperature increases, the resistance decreases (see the
graph).
If the resistance is not as specified, replace the ambient
temperature sensor.