2AD-FTV EMISSION CONTROL > SERVICE DATA



Electric EGR control valve
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (M-) - 5 (M+)
25°C (77°F)
0.3 to 100 Ω
No. 1 vacuum switching valve
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
28.3 to 31.1 Ω
Exhaust gas temperature sensor (for DPF)
for Upper Side
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
100 to 1000 kΩ
for Lower Side
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
100 to 1000 kΩ
Exhaust fuel addition injector (for DPF)
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
7.1 to 7.9 Ω
Air fuel ratio sensor (for DPF)
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (HAF2) - 2 (+B)
20°C (68°F)
1.8 to 3.4 Ω