COOLING FAN MOTOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT NO. 1 COOLING FAN MOTOR


A208241E03
  1. Disconnect the No. 1 fan motor connector.

  1. Connect the battery and an ammeter to the No. 1 fan motor connector as shown the illustration.

  1. Check that the No. 1 fan rotates smoothly, and then check the reading on the ammeter.

    Standard Current:
    7.8 to 11.8 A at 20°C (68°F)
    Text in Illustration 
    *1
    Component without harness connected
    (No. 1 Cooling Fan Motor)
    If the result is not as specified, replace the No. 1 cooling fan motor.
  1. Reconnect the No. 1 fan motor connector.



2. INSPECT NO. 2 COOLING FAN MOTOR


A208242E02
  1. Disconnect the No. 2 fan motor connector.

  1. Connect the battery and an ammeter to the No. 2 fan motor connector as shown the illustration.

  1. Check that the No. 2 fan rotates smoothly, and then check the reading on the ammeter.

    Standard Current (for Manual Transaxle):
    7.8 to 11.8 A at 20°C (68°F)

    Standard Current (for Automatic Transaxle):
    10.6 to 16.6 A at 20°C (68°F)
    Text in Illustration 
    *1
    Component without harness connected
    (No. 2 Cooling Fan Motor)
    If the result is not as specified, replace the No. 2 cooling fan motor.
  1. Reconnect the No. 2 fan motor connector.