INTAKE AIR TEMPERATURE SENSOR > INSPECTION

for Preparation Click here



1. INSPECT INTAKE AIR TEMPERATURE SENSOR
  1. Partially immerse the sensor in water and warm up the water.



  1. Measure the resistance according to the value(s) in the table below.


    A203929E02

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    2.21 to 2.65 kΩ
    60°C (140°F)
    0.54 to 0.62 kΩ

    NOTICE:
    When checking the sensor in water, keep the terminals dry. After the check, wipe the sensor dry.
    If the result is not as specified, replace the intake air temperature sensor.