ENGINE SWITCH (w/ Entry and Start System) > INSPECTION |
for Preparation Click here
1. INSPECT ENGINE SWITCH |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Switch Condition Specified Condition 7 (SS1) - 5 (GND) Not pushed 10 kΩ or higher 2 (SS2) - 5 (GND) Not pushed 10 kΩ or higher 7 (SS1) - 5 (GND) Pushed Below 1 Ω 2 (SS2) - 5 (GND) Pushed Below 1 Ω
Apply battery voltage to the terminals of the switch and check the illumination condition of the switch.
- Standard:
Measurement Condition Specified Condition Battery positive (+) → Terminal 11 (SWIL)
Battery negative (-) → Terminal 4 (COM) or 5 (GND)Illuminates (illumination of lettering) Battery positive (+) → Terminal 12 (INDS)
Battery negative (-) → Terminal 4 (COM) or 5 (GND)Illuminates (green) Battery positive (+) → Terminal 13 (INDW)
Battery negative (-) → Terminal 4 (COM) or 5 (GND)Illuminates (amber)
- HINT:
- If the positive (+) lead and the negative (-) lead are incorrectly connected, the engine switch indicator light will not illuminate.
- If the voltage is too low, the indicator light will not illuminate.