Workshop

HYDRA-MATIC 6L80 (6 Speed)

26. Install the nine (9) 55mm length valve body
bolts in the locations shown in Figure 147, and
hand tighten only at this time.
27. Install the six (6) 45mm length valve body
bolts in the locations shown in Figure 147, and
hand tighten only at this time.
28. Install the manual shift Internal Mode Switch,
as shown in Figure 148, using only one 55mm
long valve body bolt in the location shown and
hand tighten only at this time.
Note: Align the switch activator slide with the
manual valve, as shown in Figure 148.
29. Connect and lock the internal mode switch
electrical connector to Solenoid Body/TCM.
Figure 147
Figure 148
B
C
D
E
F
A
24237735
7 73 5 6 1 7 90 22 0 6
F 0 0 H Z 0 G 0 3 2
55mm LENGTH
(QUANTITY 4)
55mm LENGTH
(QUANTITY 5)
45mm LENGTH
(QUANTITY 6)
AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
86
Copyright © 2007 ATSG
VALVE/SOLENOID BODY ASSEMBLY (CONT'D)
Continued on Page 87
55MM LENGTH BOLT
INTERNAL
MODE SWITCH
MANUAL
VALVE
MANUAL
VALVE
ELECTRICAL
CONNECTOR