Workshop

HYDRA-MATIC 6L80 (6 Speed)

219 OIL PUMP COVER ASSEMBLY
229 1-2-3-4 AND 3-5 REVERSE HOUSING THRUST WASHER
230 1-2-3-4 AND 3-5 REVERSE SEAL RINGS (3 REQUIRED)
229
219
230
Caution: DO NOT
Remove These
6 Bolts
203 TORQUE CONVERTER HOUSING (MODEL DEPENDENT)
212 OIL PUMP SLIDE (SELECTIVE)
215 OIL PUMP SLIDE PIVOT PIN AND SPRING ASSEMBLY
217 OIL PUMP ROTOR (SELECTIVE)
212
215
217
203
AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
44
Copyright © 2007 ATSG
Copyright © 2007 ATSG
ROTOR .001 - .0015
SLIDE .001 - .002
Copyright © 2007 ATSG
Figure 63 Figure 65
Figure 64
18. Place the converter housing on a flat surface
with worm track surface facing up, as shown
in Figure 64.
19. Ensure that all slide seals are left out.
20. Lay a straight edge across the surface over the
slide and rotor, as shown in Figure 65.
21. Measure the clearance between the slide and
the straight edge, as shown in Figure 65. The
clearance should be .001"-.002" with no seals
in the slide.
22. Measure the clearance between the rotor and
the straight edge, as shown in Figure 65. The
clearance should be .001"-.0015"
Note: These measurements may also be done
with a depth micrometer.
23. If replacements are needed, use the chart in
Figure 66 to make your selections based on
the clearance recorded and the thickness of
the current slide and rotor.
OIL PUMP ASSEMBLY (CONT'D)
Continued on Page 45

Leave a Reply