Workshop

HYDRA-MATIC 6L80 (6 Speed)

AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
31
Copyright © 2007 ATSG
Copyright © 2007 ATSG
J-8763-B
HOLDING FIXTURE
DT-47605
HOLDING FIXTURE
ADAPTER
DT-47605
HOLDING FIXTURE
ADAPTER IN PLACE
J-3289-20
HOLDING FIXTURE
BASE ASSEMBLY
Figure 37
TRANSMISSION DISASSEMBLY
EXTERNAL PARTS
Figure 38
1. Remove the torque converter, as shown in
Figure 37.
2. Install holding fixture J-8763-B, as shown in
Figure 37, using fixture adapter DT-47605 if
necessary and is shown in place in Figure 38.
3. Rotate transmission in fixture so that converter
housing is facing up and secure with locking
pin in fixture base.
4. Allow any remaining transmission fluid to
drain from the extension housing.
5. Rotate transmission so that bottom pan is
facing up as shown in Figure 39.
Continued on Page 32