SHIFT LOCK SYSTEM > INSPECTION |
for Preparation Click here
1. INSPECT KEY INTER LOCK SOLENOID |
Disconnect the solenoid connector.
Connect the battery's positive (+) lead to terminal 1 (KLS+) and the battery's negative (-) lead to terminal 2 (KLS-).
Check that the operating noise of the solenoid can be heard.