AIR FUEL RATIO SENSOR > INSTALLATION

for Preparation Click here



1. INSTALL AIR FUEL RATIO SENSOR


    A183535E03
  1. Using SST, install the air fuel ratio sensor.

    SST
    09224-00010  

    Torque:
    without SST:
    44 N*m{ 449 kgf*cm , 32 ft.*lbf }
    with SST:
    40 N*m{ 408 kgf*cm , 30 ft.*lbf }

    NOTICE:
    1. This torque value can be obtained by using a torque wrench with a fulcrum length of 300 mm (11.81 in.) and SST with a measure of 30 mm (1.18 in.) (Click here).
    2. This torque value is effective when SST is parallel to the torque wrench.


    A181790
  1. Connect the air fuel ratio sensor connector and wire harness clamp.



2. INSTALL NO. 1 EXHAUST MANIFOLD HEAT INSULATOR


A167279
  1. Install the No. 1 exhaust manifold heat insulator with the 4 bolts.

    Torque:
    12 N*m{ 122 kgf*cm , 9 ft.*lbf }


3. INSPECT FOR EXHAUST GAS LEAK